Choose your Region

Are you sure you want to proceed?

You will be leaving the Cook Medical website that you were viewing and going to a Cook Medical website for another region or country. Not all products are approved in all regulatory jurisdictions. The product information on these websites is intended only for licensed physicians and healthcare professionals.

Critical Care

Difficult airway products


Our airway management products are designed to facilitate successful intubation, extubation, airway exchange, and emergency airway access. View each product’s indications for use, specifications, components, and other resources by clicking the links below.

Intubation

Aintree Intubation Catheter with Rapi-Fit® Adapters

G10789_P_001Used for assisted fibreoptic intubation and for uncomplicated, atraumatic endotracheal tube exchange.

Features and benefits
•  The catheter’s inner diameter (ID), lumen, and distal sideports are designed to enhance airflow.
•  The large ID permits the use of a bronchoscope, which enhances visualisation.
•  The removable Rapi-Fit adapters permit oxygen delivery, if necessary.

View more details about the Aintree Intubation Catheter with Rapi-Fit Adapters.
 
 
 

Cook® Retrograde Intubation Set 

G10554_P_15460Used to assist in the placement of an endotracheal tube during difficult or emergency airway access procedures where visualisation of the vocal cords is not possible secondary to secretions, blood, and/or anatomic anomalies.

Features and benefits
•  Uses the Seldinger technique via the cricothyroid membrane for initial access permits retrograde (cephalad) placement of a wire guide that exits orally or nasally.
•  The catheter’s tapered tip allows smoother navigation through the patient’s anatomy.

View more details about the Cook Retrograde Intubation Set.
 
 

Frova Intubating Introducer

G12591_P_002Used to facilitate endotracheal intubation in patients where the visualisation of the glottis is inadequate. The product has been designed for use by physicians trained and experienced in airway management techniques. Standard techniques for placement of intubation catheters should be employed.

Features and benefits
•  The blunt, angled tip can be passed blindly into the trachea when visualisation of the glottis is inadequate to guide the placement of the endotracheal tube.
•  The optional stiffening cannula adds rigidity to the proximal and middle sections of the catheter, but the distal portion remains flexible.

View more details about the Frova Intubating Introducer
 

Extubation

Cook Staged Extubation Set

G24073_P_002Used for staged extubation and subsequent reintubation.

Features and benefits
•  The soft, tapered, and kink-resistant wire is coated in a polymeric jacket to assure minimal irritation while in position.
•  The staged reintubation catheter allows quick access and oxygen delivery to help stabilise the patient.

View more details about the Cook Staged Extubation Set.
 
 
 
 

Airway Exchange

Arndt Airway Exchange Catheter Set with Rapi-Fit Adapters

G11920_P_13502Used for the exchange of laryngeal mask airways and endotracheal tubes using a fibreoptic bronchoscope, bronchoscopic port, wire guide, and exchange catheter. The product may be used for emergency, urgent, and elective airway management. The removable Rapi-Fit Adapter permits use of ventilator device, if necessary, during exchange procedure.

Features and benefits
•  The use of a bronchoscope enhances visualisation to facilitate clearer navigation through the patient’s anatomy.
•  The wire guide can be inserted through the working channel of the bronchoscope, which allows acute angles to be manoeuvred.

View more details about the Arndt Airway Exchange Catheter Set with Rapi-Fit Adapters.

Cook Airway Exchange Catheter with Rapi-Fit Adapters

G07833_P_002Used for uncomplicated, atraumatic endotracheal tube exchange.

Features and benefits
•  The blunt tip of the catheter is designed to be atraumatic to internal structures.
•  The lumen and distal sideports are designed to deliver oxygen.
•  The centimetre markings facilitate accurate alignment with endotracheal tubes.

View more details about the Cook Airway Exchange Catheter with Rapi-Fit Adapters.
 
 
 
 

Cook Airway Exchange Catheter – Double Lumen Extra Firm Soft Tipped

G36401_P_001Used for uncomplicated, atraumatic endotracheal tube exchange.

Features and benefits
•  The blunt, soft, and flexible tip of the catheter is designed to be atraumatic to internal structures. The distal section of the catheter is flexible.
•  The extra-firm catheter facilitates the exchange of double-lumen shaft tubes.

View more details about the Cook Airway Exchange Catheter – Double Lumen Extra Firm Soft Tipped.
 
 
 
 

Emergency Airway

Arndt Emergency Cricothyrotomy Catheter Set

G08251_P_001Used for emergency airway access when endotracheal intubation and/or ventilation cannot be performed. Airway access is achieved utilising percutaneous entry (Seldinger) technique via the cricothyroid membrane. Subsequent dilation of the tract and tracheal entrance site permits passage of the emergency airway catheter.

Features and benefits
•  Airway access is achieved by using the Seldinger technique via the cricothyroid membrane.
•  The subsequent dilation of the tract and tracheal entrance site permits the passage of the emergency airway.

View more details about the Arndt Emergency Cricothyrotomy Catheter Set.
 

Emergency Transtracheal Airway Catheter

 G10338_P_001Used for emergency airway access when conventional endotracheal intubation cannot be performed.

Features and benefits
•  The catheter is made of reinforced coils to prevent kinking.

View more details about the Emergency Transtracheal Airway Catheter.
 
 
 
 
 
 

Enk Oxygen Flow Modulator Set

G12398_P_11168Used for emergency airway access when conventional endotracheal intubation cannot be performed. The Enk Oxygen Flow Modulator allows manually controlled oxygen flow and is intended for emergency transtracheal catheter ventilation when conventional ventilation by mask or endotracheal tube cannot be performed.

Features and benefits
•  The set provides clinicians with a compact solution for quickly establishing an airway and using jet ventilation to stabilise a patient in an emergent situation.
•  The wire-reinforced catheter is designed to resist kinking and to prevent the airway device from collapsing after it is placed.

View more details about the Enk Oxygen Flow Modulator Set.

Melker Emergency Cricothyrotomy Catheter Set – Cuffed

G29432_P_002Used to establish emergency airway access when endotracheal intubation cannot be performed.

Features and benefits
•  Airway access is achieved by using the Seldinger technique or the surgical technique via the cricothyroid membrane.
•  The airway catheter is cuffed to protect and control the airway after it is placed.

View more details about the Melker Emergency Cricothyrotomy Catheter Set – Cuffed.
 
 
 
 

Melker Emergency Cricothyrotomy Catheter Set – Uncuffed

C-MELKERUsed to establish emergency airway access when endotracheal intubation cannot be performed. Airway access is achieved using percutaneous entry (Seldinger) technique via the cricothyroid membrane. Subsequent dilation of the tract and tracheal entrance site permits passage of the emergency airway catheter.

Features and benefits
•  Airway access is achieved by using the Seldinger technique via the cricothyroid membrane.
•  The uncuffed airway catheter comes in a variety of sizes.

View more details about the Melker Emergency Cricothyrotomy Catheter Set – Uncuffed.
 
 

Patil Emergency Cricothyrotomy Catheter Set

G07796_P_00107Used for emergency airway access when conventional endotracheal intubation cannot be performed.

Features and benefits
•  Airway access is achieved by using direct percutaneous puncture via the cricothyroid membrane.
•  The catheter is kink-resistant, is made of reinforced coils, and has a standard 15 mm connector and Luer lock connecter to allow oxygen delivery.

View more details about the Patil Emergency Cricothyrotomy Catheter Set.
 
 
 
 
 

Accessories

Multipurpose Plastic Tubing Adapter

G05302_P_001Used for catheter connections. The adapter is a male Luer lock to universal taper.

View more details about the Multipurpose Plastic Tubing Adapter.
 
 
 
 
 
 
 
 
 

Rapi-Fit® Adapter

G33019-RapiFitIntended for use with a Cook Airway Exchange Catheter (CAE Catheter). The French size indicated in the order number refers to the French size of the CAE Catheter.

The Rapi-Fit adapter with 15 mm connector permits the use of a ventilator device for oxygenation during exchange procedures, and the Multipurpose Tubing adapter has been designed for suction.

The product is intended for use by physicians trained and experienced in diagnostic and interventional techniques. Standard endotracheal techniques should be employed.

Features and benefits
•  Allows our airway catheters to be attached to a ventilatory device to provide oxygenation during intubation, exchange, or extubation procedures, if necessary.

View more details about the Rapi-Fit Adapter.

Thank You for Your Interest in Cook Medical's Products

The product information on this website is intended only for physicians and healthcare professionals licensed in the European Union (except France), the United Kingdom, Switzerland, Norway, Iceland, Turkey, and Liechtenstein. If you are located in another global region, please click on the regional flag at the very top of the webpage and choose your region from the drop-down options.

If your region is not listed, visit our How to Order section for more information.

Information provided on this site is not intended to be professional medical advice. Product Instructions for Use (IFU) should be consulted before use of any product.

Decline